Research

Imaging algorithms

How closely can two small blood vessels lie before they merge into one feature on an ultrasound image? We study how the signals from individual transducer elements can help separate those vessels. In our work on power Doppler, we used null subtraction imaging to sharpen the lateral response. The rat brain images below compare this approach with conventional delay-and-sum beamforming on data acquired without a contrast agent.

Six power Doppler images of rat brain vessels, with delay-and-sum on the left and null subtraction imaging on the right.
Read across each row to compare the same vessels under one clutter filter. The three rows show how the comparison changes with the choice of filter. Kou et al., IEEE Transactions on Medical Imaging (2024), Fig. 18.

FPGA acceleration

A plane-wave transmission insonifies a broad field at once. Reconstructing the image still requires aligning and summing echoes from many receive channels for every pixel. We designed a beamformer that reuses delay calculations and processes multiple samples in parallel on a single field-programmable gate array (FPGA). We evaluated its output on B-mode imaging, power Doppler and ultrasound localization microscopy.

Four stages of the parallel beamformer, from fetching delay indices and echo samples to summing samples and forming pixels.
The hardware fetches echo samples using a shared delay profile. Diagonal sums across the stacked samples form pixels at the same depth. Kou et al., IEEE Transactions on Biomedical Circuits and Systems (2023), Fig. 2.

Through-tissue ultrasound communication

Can a small transmitter send video from inside the body using sound? We used a miniature ultrasonic transducer to send a camera signal through tissue to an external receiver array. Our modem distributed the data across many acoustic subcarriers and combined signals from the receiving elements to recover the video despite echoes along the propagation path.

Example frame from the video experiment using an acoustic link through a rabbit abdomen.